ZAWÓR TERMOSTATYCZNY DN10 3/8 PROSTY z nastawą skokową
6012 00001
![](data:image/jpeg;base64,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)
Zawory termostatyczne przeznaczone są do montażu na grzejniku centralnego ogrzewania po stronie przewodu zasilającego. W zestawie z głowicą termostatyczną regulują temperaturę w pomieszczeniu poprzez zmianę przepływu czynnika grzewczego przez grzejnik. Zastosowanie termostatycznych zaworów grzejnikowych pozwala na indywidualną regulację temperatury w każdym pomieszczeniu.
Zawory termostatyczne posiadają możliwość ustawiania nastawy wstêpnej. Realizację nastawy wstępnej dokonuje się po zdjęciu głowicy z zaworu termostatycznego za pomocą klucza płaskiego S 13. Obracając tuleję obrotową ustawiamy znak na tulei na odpowiednią liczbę na skali nastaw wstępnych naniesionych na czole korpusu wkładki zaworowej.
Budowa i umiejscowienie :
Grzejnikowy zawór termostatyczny składa się z głowicy termostatycznej oraz zaworu grzejnikowego. Zależnie od typu grzejnika zawory montowane są na przewodzie doprowadzającym wodę do grzejnika lub są w niego wbudowane. W przypadku grzejników członowych aluminiowych i żeliwnych oraz grzejników stalowych płytowych typu C, z podłączeniem z boku, zawór montowany jest na przyłączu. Grzejniki stalowe płytowe typu V, które podłącza się od dołu przewodami prowadzonymi w podłodze, mają zawór wbudowany. Stanowi on integralną część urządzenia. Wówczas głowicę kupuje się osobno. Zawór może współpracować tylko z określonymi typami głowic. Producenci podają, do jakich zaworów można stosować produkowane przez nich głowice.
Regulacja temperaury w pomieszczeniu :
Głowica termostatyczna zamontowana na zaworze reguluje stopień jego otwarcia. Pozwala ustawić żądaną temperaturę pomieszczenia w szerokim zakresie, najczęściej w granicach od 6 do 28°C. Większość modeli wyposażona jest w dodatkowe funkcje, na przykład pamięć temperatury komfortu lub funkcję ograniczenia nastawy temperatury. Niektóre mają zdalne czujniki i/lub nastawę temperatury. Czujniki i nastawniki te można zamontować w dowolnym miejscu, do którego będzie swobodny dostęp.
Zawór termostatyczny, zależnie od potrzeb, otwiera bądź zamyka zawór grzejnikowy. W ten sposób regulowana jest ilość ciepła oddawanego przez grzejnik, a więc i temperatura w pomieszczeniu. Następuje to zazwyczaj poprzez obrót pokrętła głowicy, na którym znajduje się skala zwykle od 1 do 5 (położenie 5 to pełne otwarcie zaworu, czyli praca z maksymalną mocą).
Optymalna temperatura (czyli taka, w której nie jest ani za zimno, ani za gorąco) jest wtedy, kiedy wskaźnik znajduje się mniej więcej w połowie skali. Każda osoba odczuwa komfort przy nieco innej temperaturze, ale zwykle kiedy jest się normalnie ubranym i nie wykonuje się ciężkiej pracy fizycznej waha się ona między 20 a 22°C. Zaleca się, aby na noc obniżać temperaturę do 18°C. Utrzymywanie temperatury na poziomie 25°C jest wskazane jedynie w łazienkach, ze względu na chłód odczuwany po wyjściu z wanny czy spod prysznica. Ustawienie pokrętła głowicy w położeniu 1 spowoduje utrzymywanie w pomieszczeniu tzw. temperatury dyżurnej (ok. 6°C), która zabezpiecza instalację przed zamarznięciem w niej wody. Takie postępowanie jest zalecane, gdy nikt nie korzysta z pomieszczenia przez co najmniej kilka dni. Zwykle możliwe jest też przestawienie głowicy w położenie całkowicie odcinające dopływ wody do grzejnika. Głowice termostatyczne montowane do zaworów grzejnikowych samoczynnie zamykają je lub otwierają, tak że w pomieszczeniu utrzymywana jest stała temperatura. Ich zastosowanie jest bardzo korzystne, gdyż pozwala ograniczyć zużycie energii nawet o kilkadziesiąt procent (w porównaniu z sytuacją, kiedy w instalacji nie ma żadnych automatycznych regulatorów), a zawór z głowicą kosztuje jedynie kilkadziesiąt złotych.
Dane Techniczne :
Zawór termostatyczny DN10 3/8 gz x3/8 gw Prosty